Industrial firewall: role, difference with an IT firewall, OT segmentation, data diode and choosing one for the plant

Published on November 16, 2026

An industrial firewall filters traffic between the zones of a plant network and between the plant and business IT. It differs from an office firewall in its enclosure, built for the control cabinet, and in its ability to read PLC protocols such as Modbus or S7. In France, ANSSI, the national cybersecurity agency, sets the expected device by system class: a firewall for the lower classes, a unidirectional gateway and then a qualified data diode for the most critical ones.

Industrial firewall: what it is for

A plant network connects PLCs, supervisory workstations, robots and servers. Without separation, an intrusion on an office workstation can reach the machines. The industrial firewall splits this network into zones and only lets the planned exchanges through between them. The iec 62443 standard calls these zones and their controlled links zones and conduits: the firewall is the device that controls a conduit.

The need is measured. In its annual report published on 17/02/2026, Dragos states that 81% of its assessments found poor IT/OT segmentation, and that 73% of all the incidents it has handled involved compromised VPN or jump server credentials. The attack on refrigeration controllers in October 2026, covered in our article on the industrial cyberattack, targeted devices reachable from the internet.

How it differs from an IT firewall

  • The enclosure: DIN rail mounting in the cabinet, extended temperature range, no fan. The Cisco ISA3000 operates from -40 to +74 °C according to its data sheet, the Stormshield SNi50 from -40 to +70 °C.
  • Production continuity: bypass ports let traffic through if the unit fails. The SNi50 has two pairs.
  • Reading industrial protocols: beyond addresses and ports, the firewall inspects the content of exchanges (deep packet inspection, or DPI). It can allow reading a Modbus register and block writing to it. The Cisco ISA3000 data sheet lists Modbus, Siemens S7, OPC UA, EtherNet/IP, CIP and DNP3, among others.
  • Field standards: IEC 62443-4-2 component certification, electromagnetic compatibility for electrical substations (IEC 61850-3).

What ANSSI requires by system class

The guide "Cybersecurity for industrial control systems: detailed measures", version 2.0 of 27/11/2025, classifies industrial systems from class 1 to class 4, the most critical. It describes security functions rather than products, to leave the choice of solution open, but it names the firewall and the diode at each level:

  • All classes: split the system into separated zones, deny all flows by default and only allow those that are needed, protect the interconnection with business IT with a firewall, or with two firewalls in the reinforced version, and prohibit any direct internet access, in either direction.
  • Class 2: one-way flows towards business IT, controlled at least by a firewall.
  • Class 3: one-way flows provided by a unidirectional gateway, a firewall separate from the VPN concentrator, and interconnection devices with ANSSI CSPN certification or equivalent.
  • Class 4: physical separation, one-way flows that can be provided by an ANSSI-qualified data diode, and qualified interconnection devices. Any communication from business IT to class 4 is to be prohibited.

The guide also gives examples of inspection rules: allow a single specific write to a Modbus register, or a single OPC UA write operation, between two given addresses. ANSSI also publishes configuration recommendations for Hirschmann and Siemens Scalance switches and firewalls (February 2022).

Firewall, DMZ or diode: which architecture

  • The firewall between business IT and the plant: the first level, it only lets listed flows through.
  • The intermediate zone, or industrial DMZ: shared servers (historian, update server, jump server for remote maintenance) sit in a zone between two firewalls. IT and the plant then never talk to each other directly. Cisco presents its ISA3000 as widely used as a DMZ firewall.
  • Firewalls inside the plant: between lines, or between safety PLCs and standard PLCs, so that an intrusion does not spread to the whole shop floor.
  • The data diode: a device that only lets data through in one direction, from the plant outwards. It is used for the most critical systems, when no command must be able to come back in.

The plant network architecture, its protocols and private networks are covered in our industrial 5g guide.

The main manufacturers

Examples taken from the manufacturers' official product pages, read on 16/11/2026, in no particular order:

  • Stormshield (Airbus group, France): SNi range. The SNi40 was the first industrial firewall to obtain ANSSI CSPN certification and Standard qualification, according to Stormshield; it is no longer sold and the SNi50 replaces it (-40 to +70 °C, two bypass pairs, IEC 61850-3, development compliant with IEC 62443-4-1).
  • Cisco: Secure Firewall ISA3000, DIN rail mounted, -40 to +74 °C, with a long list of inspected industrial protocols.
  • Moxa: EDR-G9010 Series, a router and firewall certified IEC 62443-4-2 Security Level 2, with deep packet inspection of industrial protocols, intrusion prevention and VPN, -40 to +75 °C in the -T version.
  • Siemens (SCALANCE range), Hirschmann (Belden group, EAGLE range), Fortinet (FortiGate Rugged), Phoenix Contact (mGuard) and TXOne also offer industrial firewalls.

None of these manufacturers shows a public price on its product page: prices are quoted by a distributor or an integrator.

How to choose an industrial firewall

  • Start from the zoning: the class of each zone, under the ANSSI method, sets the expected device (firewall, unidirectional gateway, diode) and the certification level.
  • List the protocols to inspect: those of your PLCs and supervisory systems, then check that they appear on the product data sheet.
  • Check certifications: ANSSI CSPN or qualification for classes 3 and 4, IEC 62443-4-2 for the component.
  • Plan for failure: bypass, redundant power supply, high availability.
  • Think about operations: centralised management console, logging of denied flows, skills in the team or at an integrator to keep the rules up to date.
  • Do not forget remote maintenance: remote access by machine suppliers goes through a single point, controlled by the firewall, with two-factor authentication.

Measures specific to supervisory systems are covered in our scada security guide.

What manufacturers said at Tech for Industry Show

In his keynote at the 2026 show, Aymeric Renaud, president of Schneider Electric France, presented the case of the cement maker Vicat, which deployed probes, firewalls and sensors for its cyber compliance, then used this data to gain 6% productivity in two years, according to the speaker. Read the article

At the round table on the defence industry, Saft, represented by Éric Viriot, stated that the battery maker protects the data from its batteries with firewalls, screening and the choice of non-Chinese components. Read the article

Frequently asked questions

What is an industrial firewall?

A firewall designed for a plant network: it separates zones, only lets planned exchanges through and reads PLC protocols, in an enclosure built for the control cabinet.

What is the difference between an industrial firewall and an IT firewall?

The enclosure (DIN rail, extreme temperatures, no fan), production continuity (bypass) and inspection of industrial protocols such as Modbus, S7 or OPC UA.

Do you need a data diode or a firewall?

It depends on the system class under ANSSI: a firewall is enough for classes 1 and 2, class 3 requires a unidirectional gateway, and the qualified diode is aimed at class 4.

What is an industrial DMZ?

A zone placed between two firewalls, between business IT and the plant, holding shared servers, so that the two networks never communicate directly.

Which certification should you ask for?

IEC 62443-4-2 certification of the component, and for class 3 and 4 systems under ANSSI, a CSPN certification or an ANSSI qualification.

How much does an industrial firewall cost?

Manufacturers do not show public prices: the price depends on the model, inspection licences and support, and is quoted by a distributor or an integrator.

Further reading

Our industrial cyber security page brings together the show's talks, articles and exhibitors on this topic.