IEC 62443: parts of the standard, security levels, zones and conduits, certification and link with the CRA

Published on November 14, 2026

IEC 62443 is the international series of standards on the cybersecurity of industrial automation and control systems: PLCs, supervisory systems, plant networks. It splits the requirements between the site operator, the integrator and the equipment manufacturer. It is gaining weight in Europe, because its parts are being adapted into harmonised standards for the Cyber Resilience Act, whose main obligations apply from 11/12/2027.

IEC 62443: what the standard is for

The series is published by technical committee 65 of the International Electrotechnical Commission (IEC), which covers industrial-process measurement, control and automation. It starts from a point that ANSSI, the French cybersecurity agency, sums up as follows: industrial systems control processes that have a direct physical effect, some use information technologies without having been designed for the threats they bring, and the solutions used in business IT are not always suited to them.

The stakes are concrete for industry. According to the IBM X-Force Threat Intelligence Index 2026, manufacturing was the most targeted sector for the fifth year in a row, with 27.7% of the incidents handled by IBM's teams in 2025. The most common way in was the exploitation of internet-facing applications (32%).

Our industrial cyber security page brings together the show's talks, articles and exhibitors on this topic.

The parts of the standard

The series is split into four groups. The most cited parts, with their current edition on the IEC webstore:

  • Group 1, general: 62443-1-1 (technical specification, 2009) sets out the terminology, concepts and models, including the seven foundational requirements.
  • Group 2, policies and procedures: 62443-2-1 (edition 2.0, 07/08/2024) sets the security programme of the operator of a system in service; 62443-2-3 (technical report, 2015) covers patch management; 62443-2-4 (2023 edition) sets the requirements for service providers, integrators and maintenance providers.
  • Group 3, system: 62443-3-2 (2020) describes risk assessment and the partitioning into zones and conduits; 62443-3-3 (2013) gives the technical requirements of a system and its security levels.
  • Group 4, component: 62443-4-1 (2018) sets the manufacturer's secure development lifecycle; 62443-4-2 gives the technical requirements of a component (PLC, supervisory workstation, network device).

The 2024 part 2-1 reflects a plant reality: an industrial system can last more than twenty years, and many legacy systems are no longer updated. For them, the standard asks for compensating measures written into the operator's procedures.

Who does what: operator, integrator, manufacturer

  • The operator (site owner) defines its security programme, sets the tolerable risk and approves the requirements of each zone (parts 2-1 and 3-2).
  • The integrator or maintenance provider applies requirements on architecture, remote access, account management, patches, backups and malware protection (part 2-4).
  • The manufacturer develops its products following a secure lifecycle (part 4-1) and gives them the expected security functions (part 4-2).

This split is useful in contracts: a manufacturer can ask a supplier to comply with the part that concerns it.

Zones and conduits

Part 3-2 partitions the system into zones, which group equipment with common security requirements, and conduits, which are the controlled links between two zones. For example: separating business IT from control systems, isolating safety systems, handling wireless or temporarily connected devices separately.

The approach follows seven steps: define the system and its access points, carry out an initial risk assessment, partition into zones and conduits, compare the risk with the tolerable risk, carry out the detailed assessment that sets a target security level for each zone, document the requirements, then obtain the operator's approval. An intrusion into one zone then does not give access to the others.

The plant network architecture on which this partitioning relies is detailed in our industrial 5g guide.

Security levels SL 1 to 4

Each zone is given a target security level, derived from the risk assessment:

  • SL 1: protection against unintentional error or misuse.
  • SL 2: protection against intentional attack using simple means, few resources and general skills.
  • SL 3: protection against intentional attack using sophisticated means, moderate resources and knowledge of automation systems.
  • SL 4: the same attack, with extensive resources and high motivation.

Part 3-3 distinguishes the level targeted for a zone (SL-T) from the level a system is capable of reaching (SL-C). Its technical requirements derive from the seven foundational requirements defined in part 1-1. Aiming for SL 4 everywhere makes no sense: the level follows the risk of each zone.

The manufacturer's maturity levels

Part 4-1 assesses the manufacturer's development practices on four maturity levels: initial (ad hoc development), managed (written rules and trained teams), defined (process applied across the organisation, with evidence) and improving (metrics and continuous improvement). All the requirements of a level must be applied: picking only some of them does not make a supplier compliant.

IEC 62443 certification

The standard does not certify a plant by itself: certification bodies issue certifications. The ISASecure programme, linked to the International Society of Automation, offers several:

  • SDLA: the manufacturer's secure development lifecycle, under part 4-1;
  • CSA: security of a component, under part 4-2;
  • SSA: security of a system, under part 3-3;
  • ACSSA: security of an automation system in service, under parts 2-1, 2-4, 3-2 and 3-3.

The IEC also publishes test report forms for parts 2-1 and 3-3 in its IECEE testing system. For a buyer, a 4-1 certification says how the supplier develops; a 4-2 or 3-3 certification says what the product or system can do.

IEC 62443, the CRA and NIS2

The Cyber Resilience Act (Regulation (EU) 2024/2847) sets cybersecurity requirements for products with digital elements sold in Europe. According to the European Commission, it entered into force on 10/12/2024, reporting obligations have applied since 11/09/2026 and the main obligations apply from 11/12/2027.

The link with IEC 62443 runs through harmonised standards. Working group 3 of the CENELEC TC65X committee is adapting the EN IEC 62443 series so that it meets the essential requirements of the CRA: part 4-2 is being amended (A11:2026), as is part 4-1, and six standards target product categories in Annex III of the regulation, such as routers, VPNs and firewalls (CEN-CENELEC, September 2025). For an industrial equipment manufacturer, applying parts 4-1 and 4-2 therefore prepares for the 2027 CE marking.

On the operator side, the NIS2 directive requires risk management measures that also cover shop floor systems. Parts 2-1 and 3-2 give a method to implement them in a plant. The French timeline is tracked in our NIS2 and manufacturing guide. In France, ANSSI also publishes a classification method for industrial systems, whose current version was put online on 11/04/2025.

How to apply IEC 62443 in a plant

  • Make an inventory of PLCs, supervisory workstations, networks and remote access.
  • Define the system and its access points, then carry out an initial risk assessment.
  • Partition into zones and conduits and set a target security level for each zone.
  • Write the operator's security programme (part 2-1), including compensating measures for legacy systems.
  • Require suppliers to meet the part that concerns them: 2-4 for the integrator, 4-1 and 4-2 for the manufacturer.
  • Track patches and check that the measures remain effective over time.

The technical measures to protect a supervisory system are detailed in our scada security guide.

What manufacturers said at Tech for Industry Show

Pascal Férard, head of cybersecurity at Exotec, and Jérémie Rozenblum explained how the French warehouse robot manufacturer handles the availability of its systems and its compliance: ISO 27001, SOC 2 Type II report, NIS2 and the Cyber Resilience Act, a condition for CE marking. According to them, cybersecurity has become an "entry ticket" with large industrial groups. Read the article

In his keynote, Aymeric Renaud presented the case of the cement maker Vicat, which deployed probes, firewalls and sensors for its cyber compliance, then used this data to gain 6% productivity in two years, according to the speaker. Read the article

Frequently asked questions

What is the IEC 62443 standard?

A series of IEC international standards on the cybersecurity of industrial automation and control systems, which splits requirements between the operator, the integrator and the manufacturer.

Are IEC 62443 and CEI 62443 the same standard?

Yes: CEI is the French acronym of the International Electrotechnical Commission, IEC its English acronym.

Which part concerns a manufacturer that operates a plant?

Mainly part 2-1 (the operator's security programme) and part 3-2 (risk assessment, zones and conduits).

What is the difference between IEC 62443-4-1 and 4-2?

Part 4-1 covers how the manufacturer develops its products; part 4-2 covers the security functions of the component itself.

How do you obtain IEC 62443 certification?

Through a certification body, for example in the ISASecure programme: SDLA for part 4-1, CSA for 4-2, SSA for 3-3, ACSSA for a system in service.

How much does the standard cost?

On the IEC webstore, on 14/11/2026, part 2-1:2024 costs 405 Swiss francs and part 3-3:2013 costs 380 Swiss francs, as an electronic version for one user.

What is the link with the Cyber Resilience Act?

Parts 4-1 and 4-2 are being adapted into European harmonised standards for the CRA, whose main obligations apply from 11/12/2027.

Further reading

Our industrial cyber security page brings together the show's talks, articles and exhibitors on this topic.

Popular articles