MTBF (mean time between failures) is calculated by dividing a piece of equipment's operating time by the number of failures over the same period. Together with MTTR, the mean time to restore it, it gives availability: MTBF / (MTBF + MTTR). The calculation is simple; what makes it useful is the counting rules and the number of failures observed.
MTBF: definition
MTBF is the average operating time between two failures of a repairable asset: a machine, a pump, a conveyor. The longer it is, the less often the asset fails. It is counted in operating time, excluding voluntary or planned stops, not in calendar time.
The reference vocabulary in France is the NF EN 13306 standard, "Maintenance - Maintenance terminology", published by AFNOR in November 2017 and still in force, the French version of EN 13306:2017. It replaces the October 2010 edition. Maintenance indicators are covered by another standard, NF EN 15341+A1 of June 2022, "Maintenance - Maintenance key performance indicators", which helps choose a set of indicators to assess the effectiveness, efficiency and sustainability of maintenance.
The MTBF formula
MTBF = total operating time / number of failures.
Three related indicators go with it:
- MTTR (mean time to repair or to restoration): total downtime due to failures / number of failures. It includes diagnosis, waiting for parts and repair, depending on the rule chosen.
- MTTF (mean time to failure): average operating time before the first failure. It applies to a component that is replaced rather than repaired, such as a bearing or an electronic board.
- Availability: MTBF / (MTBF + MTTR). It is the share of time the asset can produce, counting failures only.
These three notions form the reliability, maintainability and availability triad: MTBF measures reliability, MTTR maintainability, and both together availability.
Calculating MTBF: a worked example
A press runs for a month with 600 hours of required time, once planned stops (weekends, preventive maintenance) are removed. It fails 4 times, for a total of 20 hours of downtime.
- Operating time: 600 - 20 = 580 hours.
- MTBF: 580 / 4 = 145 hours.
- MTTR: 20 / 4 = 5 hours.
- Availability: 145 / (145 + 5) = 96.7%.
- Failure rate: 1 / 145, about 6.9 failures per 1,000 operating hours.
An MTBF of 145 hours does not mean the press will run 145 hours without failing. If failures occur at random, at a constant rate, the probability that it runs up to the MTBF without failing is only about 37%: 63% of cases fail before.
Calculation pitfalls
- What counts as a failure. A two-minute minor stop, a changeover, a stop for lack of material: each plant decides what it counts. The rule is written down once and kept, otherwise MTBF varies while the machine has not changed.
- The time counted. Dividing calendar time (30 days, or 720 hours) instead of operating time inflates the MTBF of assets that run little.
- The two MTTRs. Active repair time and full downtime, including waiting for parts and for the technician, can differ widely. A published MTTR should say which one it measures.
- The number of failures. An MTBF calculated on three or four failures is fragile: one failure more or less changes it by 25%. Reliamag magazine advises treating an MTBF built on fewer than 20 to 30 failures as provisional, and saying so.
- The end of the period. If the study period ends while the machine is running, the time since the last failure does not end with a failure. Counting it as is or ignoring it gives two different results; the gap becomes small when failures are numerous.
- The average hides severity. Ten five-minute failures and one two-day failure do not have the same effect on production, but weigh comparably on MTBF.
MTBF, failure rate and the Weibull distribution
The relation "failure rate = 1 / MTBF" only holds if failures occur at a constant rate, at random, as described by the exponential distribution. This is typical of electronic components in mid-life, not of a part that wears out.
The Weibull distribution describes the three periods of an asset's life, known as the "bathtub curve", according to its shape parameter, called beta:
- Beta below 1: the failure rate decreases over time. These are early-life failures, after commissioning or a poorly done repair.
- Beta equal to 1: the rate is constant. This is the exponential distribution, and MTBF is enough to describe reliability.
- Beta above 1: the rate increases over time. This is wear-out, which calls for preventive maintenance before end of life.
Fitting a Weibull distribution to an asset's failure history therefore tells which type of maintenance suits it, which MTBF alone does not.
Predicted MTBF and observed MTBF
The MTBF on a datasheet, for example for a drive or a power supply, is not measured in your plant. It is predicted by a component reliability handbook, always stated with temperature, humidity and usage conditions: the American MIL-HDBK-217F, or the FIDES methodology, a project of the French Institute for Risk Management (IMdR), based on the physics of failures, tests and field returns, whose 2022 Edition A guide is available in English.
Observed MTBF is calculated on the history of your own failures, in your environment: dust, heat, speed, quality of maintenance. There is no free public table of MTBF by equipment type: the ISO 14224 standard gives a data collection method, without values, and the databases that publish figures, such as OREDA for oil and gas, are paid and specific to their sector. They serve as a reference, not as a target.
What is a good MTBF?
No figure applies to everyone. MTBF depends on the asset, its use and its environment. The right reference is the trend of the same machine's MTBF, with the same counting rules, month after month, and the comparison between identical machines in the same fleet. A falling MTBF signals wear or a drift in maintenance; a rising MTBF after a change of method measures its effect.
Calculating MTBF in Excel
A spreadsheet is enough for a first machine. One row per failure, with:
- the asset, the date and time the stop started and ended;
- the stop duration, the cause and the type of failure (mechanical, electrical, automation);
- the operating time for the period, taken from required time.
MTBF, MTTR and availability are then calculated by formula, per machine and per month. The limit comes as the fleet grows: missed entries, causes recorded differently from one technician to another, operating time estimated rather than measured.
Measuring MTBF with a CMMS
A cmms records every work request and work order, with its hours and cause, and calculates MTBF and MTTR per asset. Connected to machine counters or to the supervision system, it uses actual operating time rather than an estimate. This industrial data is also what predictive maintenance models rely on.
Finally, MTBF and MTTR explain part of overall equipment effectiveness: failures lower its availability rate. Tracking both together links maintenance to production.
How to improve MTBF and MTTR
- To extend MTBF: analyse recurring failures and their root cause, adjust preventive maintenance to the type of failure (wear or random), monitor the condition of critical assets with sensors.
- To reduce MTTR: keep critical spare parts in stock, document interventions, give technicians the machine's history in the field.
What manufacturers said at Tech for Industry Show
At the 2026 show, Forvia presented maintenance as one of its three priority areas for AI: 5,000 machines across 35 technology categories, increasingly scarce expertise, and a target backed by the executive committee to cut MTTR by 50%. Read the article
Among the exhibitors of the 2027 edition, CARL Software, which publishes maintenance and industrial asset management software, offers CARL Predict, an IoT platform dedicated to predictive maintenance. SpinalCom, which publishes an operational digital twin bringing together data from controllers, the CMMS and drawings, highlights improved MTTR and faster incident analysis.
Frequently asked questions
How do you calculate MTBF?
MTBF = total operating time / number of failures over the same period, excluding planned stops.
What is the difference between MTBF and MTTR?
MTBF measures the average time between two failures, so reliability; MTTR measures the average time to restore, so maintainability.
What is the difference between MTBF and MTTF?
MTBF applies to an asset that is repaired; MTTF to a component that is replaced, up to its first failure.
How do you calculate availability from MTBF and MTTR?
Availability = MTBF / (MTBF + MTTR). With an MTBF of 145 hours and an MTTR of 5 hours, it is 96.7%.
What is a good MTBF?
There is no universal value: the useful reference is the trend of the same machine's MTBF, calculated with the same rules.
Which standard defines MTBF?
Maintenance terminology is set by NF EN 13306 of November 2017; maintenance indicators by NF EN 15341+A1 of June 2022.
Further reading
Our industrial maintenance page brings together the show's talks, articles and exhibitors on industrial maintenance and asset management.